Search results for "Medical cyclotron"

showing 5 items of 5 documents

Analysis of radionuclide concentration in air released through the stack of a radiopharmaceutical production facility based on a medical cyclotron

2015

Abstract Positron emitting radionuclides are increasingly used in medical diagnostics and the number of radiopharmaceutical production facilities have been estimated to be growing worldwide. During the process of production and/or patient administration of radiopharmaceuticals, an amount of these radionuclides might become airborne and escape into the environment. Therefore, the analysis of radionuclide concentration in the air released to the stack is a very important issue to evaluate the dose to the population living around the plant. To this end, sampling and measurement of radionuclide concentration in air released through the stack of a Nuclear Medicine Center (NMC), provided with a c…

education.field_of_studyRadionuclideMedical diagnosticRadiationSettore ING-IND/20 - Misure E Strumentazione NucleariChemistrySystem of measurementNuclear engineeringPopulationDetectorCyclotronSampling (statistics)law.inventionStack (abstract data type)lawMedical cyclotron PET Radioactive air effluent RadiopharmaceuticalseducationSettore ING-IND/19 - Impianti NucleariNuclear chemistryRadiation Physics and Chemistry
researchProduct

Measurement of long-lived radionuclide activity induced in target components of a cyclotron used for [18F ]-[FDG] production

2019

The evaluation of high activity induced in target components in using a medical cyclotron to produce positron-emitting radionuclides for PET (Positron Emission Tomography) diagnostic studies is one of important issue and involves radiation protection concepts when operators are engaged in maintenance and/or substitution of a target or its components. Most of replaced target components are generally classified and stored in a Pb-shielded container in order to wait for their radioactive decay. However, after some years, it can be necessary to start with the removal of the oldest parts, for a temporary storage of the fresh activated ones. The feasibility of these operations and the waste final…

gamma-ray spectrometryFDG productionSettore ING-IND/20 - Misure E Strumentazione Nuclearimedical cyclotronactivationSettore ING-IND/19 - Impianti Nucleari
researchProduct

THERP and HEART integrated methodology for human error assessment

2015

Abstract THERP and HEART integrated methodology is proposed to investigate accident scenarios that involve operator errors during high-dose-rate (HDR) treatments. The new approach has been modified on the basis of fuzzy set concept with the aim of prioritizing an exhaustive list of erroneous tasks that can lead to patient radiological overexposures. The results allow for the identification of human errors that are necessary to achieve a better understanding of health hazards in the radiotherapy treatment process, so that it can be properly monitored and appropriately managed.

RadiationComputer scienceProcess (engineering)Medical cyclotronHuman errorFuzzy setTechnique for Human Error Rate PredictionFuzzy logicReliability engineeringIdentification (information)PETRadiotherapy treatmentRadiopharmaceuticalsRadioactive air effluentSettore ING-IND/19 - Impianti Nucleari
researchProduct

Analysis of radionuclide concentration in air released through the stack of a radiopharmaceutical production facility

2014

The quantities of positron emitting radionuclides used in medical diagnostics and the number of radiopharmaceutical production facilities have been estimated to be growing worldwide. In this field, an amount of these radionuclides might become airborne and escape into the environment during the process of production and/or during administration by hospital personnel. Therefore, the analysis of dose to the operating staff as well as to the public, due to releases through the stack, is a very important issue. To this end, sampling and measurement of radionuclide concentration in air released through the stack of a Nuclear Medicine Center (NMC), provided with a cyclotron for radiopharmaceutica…

Medical cyclotron radioactive air effluent PET Potential dose.Settore ING-IND/20 - Misure E Strumentazione Nucleari
researchProduct

Analysis of Air Discharges from a PET Radiopharmaceuticals Production Center Based on a Cyclotron

2012

The control of air contamination in a Nuclear Medicine Center (NMC) provided with a cyclotron for the production of radiopharmaceuticals is based on an automatic systems for air sampling and measurements. An important control for the assessment of dose to the population is aimed at the measurement of air concentration of stack release and inside the cyclotron vault during irradiation. The frequency of sampling can be setup as continuous with respect to the stack effluent release and cyclic for other work environments. The gamma-ray spectrometric measurement are made on-line and for a short time by using a shielded Marinelli beaker filled with sampled air and a gamma detector. The use of thi…

Settore ING-IND/20 - Misure E Strumentazione NucleariMedical cyclotron PET radioactive air effluent
researchProduct